Techno T-Grid Ceiling Installation Details
Site conditions:
symbol
Modular ceilings are among the last equipments to be installed at the site because it is a pre-finished product. Therefore, the building is expected to be in suitable condition, with regard to humidity, cleanliness etc., before installation of modular ceiling begins.
symbol The installation site is expected to be fully enclosed and all wet work should be completed beforehand and dried.
symbol All installations (ducting, insulation etc.) must be installed before laying the T-Grid system and Techno ceiling tiles.
Leveling:
symbol
Sufficient information shall be clearly indicated on the drawings to enable the ceiling module and setting out points in each ceiling area applicable to all relevant trades to be established early.
symbol
The ceiling height in each area shall be marked in relation to the elevation bench marks and then transferred by means of water level.
Top fixings:
symbol The suitability of the site will be verified before installing the suspension system.
symbol The top fixings are best installed with the T-grid system as this will maintain the dimensional integrity.
Hangers:
symbol
When the hangers cannot be installed at the recommended dimensions, an appropriate suitable sub grid will be installed based on the site dimensions.
symbol
Hangers to be installed will be vertical or nearly vertical and shall not press against insulation covering ducts or pipes. If hangers have to be fixed diagonally to avoid obstructions the horizontal force shall be offset by bracing.
Main Runners:
symbol
Leveling of the main runners shall be done with the supporting hangers. This will prevent downward movement when tiles are loaded
symbol
To ensure proper levelling, any bending of the material will never be undertaken.
symbol
The main runners shall be suspended by means of a GI wire of 2/2.5mm diameter or 4mm rod at every 1.2m and not more than 150mm from the spliced joints.
symbol
The last hanger at the end of each main runner should not be more than 450mm from the adjacent wall.
Hanger Wires:
symbol
The loops shall be sharply bent and tightly wrapped to prevent vertical movement of the runner within the loop, wherever it passes through the main runner.
symbol
The wire shall be wrapped around itself a minimum of the full turns within a 3 inches length.
Cross Tees:
symbol Cross tees are installed on the main runners in a right angle.
symbol The 1200mm long Techno Cross Tee is attached to two main T section.
symbol Then the 600mm long Techno Cross T is filled between 2 sections of 1200 cross T's.
Wall Angle:
symbol The wall angles are neatly joined around the corners. The straight line wall angles shall be completely in line.
symbol The wall angles shall be firmly screwed to the wall at every 300mm.